Megawavz Automation - We ship worldwide !

OPEN: We deliver to USA , Canada and parts of Asia-Europe, during Covid crisis *

Wilcom T-207 Longitudinal Balance Test Set

Request Quote

Wilcom T-207 Longitudinal Balance Test Set

Request Quote

1 in stock

  • Condition: In use when removed
  • Manufacturer: Wilcom
  • Model: T-207
SKU: 3d65824c0a13 Category: Tag:

The T207 Longitudinal Balance Test Set is designed to measure the longitudinal balance of single-port or two-port circuits and devices. This test set permits evaluation of relays, feed coils, networks, long-line units, amplifiers and other equipment present on the typical communications circuit. These devices may have poor longitudinal balance and thus contribute to the susceptibleness of the facility.

The measuring technique and circuit configuration conforms to the IEEE standard 455-1976 for Longitudinal Balance Measurements. Longitudinal balance measurements may be made at single frequencies in the range of 40 Hz to 4 kHz. Also, as an added feature of the Model T207, a figure of merit balance measurement may be made using a shaped waveform which is representative of a power induced noise spectral distribution. Single frequency measurements on circuits with balance approaching 80 dB can be made with a typical accuracy of ? 1 dB.

Features and Benefits:
Balance Measurements: 10 to 90 dB
Direct Reading of Balance in dB
Measure 1-Port and 2-Port Circuits or Devices
Quasi-rms Meter Circuit
Built-in Calibration Circuit
Built-in Longitudinal Signal Sources Single Frequency Tests:
40 Hz to 4 kHz; 1v/10v
Broad Band Signal: 1v
DC Current Source for Circuits Under Test
Verification of Validity of Measurement

Unit has no cover

Additional Information

Weight 25 kg

*To business addresses in cities that are not under mandatory lockdown. E-mail us with your shipping address for details.